Search Results (573 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-39537 1 Juniper 7 Acx7020, Acx7024, Acx7024x and 4 more 2026-01-23 6.5 Medium
An Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Juniper Networks Junos OS Evolved on ACX 7000 Series allows an unauthenticated, network-based attacker to cause a limited information disclosure and availability impact to the device. Due to a wrong initialization, specific processes which should only be able to communicate internally within the device can be reached over the network via open ports. This issue affects Junos OS Evolved on ACX 7000 Series: * All versions before 21.4R3-S7-EVO, * 22.2-EVO versions before 22.2R3-S4-EVO, * 22.3-EVO versions before 22.3R3-S3-EVO, * 22.4-EVO versions before 22.4R3-S2-EVO, * 23.2-EVO versions before 23.2R2-EVO, * 23.4-EVO versions before 23.4R1-S1-EVO, 23.4R2-EVO.
CVE-2025-61939 1 Columbiaweather 2 Weather Microserver, Weather Microserver Firmware 2026-01-23 8.8 High
An unused function in MicroServer can start a reverse SSH connection to a vendor registered domain, without mutual authentication. An attacker on the local network with admin access to the web server, and the ability to manipulate DNS responses, can redirect the SSH connection to an attacker controlled device.
CVE-2024-37144 1 Dell 5 Data Lakehouse, Insightiq, Powerflex Appliance Intelligent Catalog and 2 more 2026-01-23 8.2 High
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster.
CVE-2025-58742 1 Milner 1 Imagedirector Capture 2026-01-22 N/A
Insufficiently Protected Credentials, Improper Restriction of Communication Channel to Intended Endpoints vulnerability in the Connection Settings dialog in Milner ImageDirector Capture on Windows allows Adversary in the Middle (AiTM) by modifying the 'Server' field to redirect client authentication.This issue affects ImageDirector Capture: from 7.0.9 before 7.6.3.25808.
CVE-2025-14376 1 Rockwellautomation 1 Verve Asset Manager 2026-01-21 N/A
A security issue was discovered within the legacy ADI server component of Verve Asset Manager, caused by plaintext secrets stored in environment variables on the ADI server. This component has been retired and has been optional since the 1.36 release in 2024.
CVE-2025-12357 2 Iec, Iso 15118-2 Network And Application Protocol Requirements 2 Ev Car Chargers, Ev Car Chargers 2026-01-16 8.3 High
By manipulating the Signal Level Attenuation Characterization (SLAC) protocol with spoofed measurements, an attacker can stage a man-in-the-middle attack between an electric vehicle and chargers that comply with the ISO 15118-2 part. This vulnerability may be exploitable wirelessly, within close proximity, via electromagnetic induction.
CVE-2023-30767 1 Intel 1 Optimization For Tensorflow 2026-01-15 5.5 Medium
Improper buffer restrictions in Intel(R) Optimization for TensorFlow before version 2.13.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-15464 1 Yintibao 1 Fun Print Mobile 2026-01-13 7.5 High
Exported Activity allows external applications to gain application context and directly launch Gmail with inbox access, bypassing security controls.
CVE-2025-21045 1 Samsung 12 Galaxy Watch, Galaxy Watch 4, Galaxy Watch 4 Classic and 9 more 2026-01-10 4 Medium
Insecure storage of sensitive information in Galaxy Watch prior to SMR Oct-2025 Release 1 allows local attackers to access sensitive information.
CVE-2023-37540 1 Hcltech 1 Sametime 2026-01-09 3.9 Low
Sametime Connect desktop chat client includes, but does not use or require, the use of an Eclipse feature called Secure Storage. Using this Eclipse feature to store sensitive data can lead to exposure of that data.
CVE-2023-52832 2 Linux, Redhat 2 Linux Kernel, Enterprise Linux 2026-01-05 9.1 Critical
In the Linux kernel, the following vulnerability has been resolved: wifi: mac80211: don't return unset power in ieee80211_get_tx_power() We can get a UBSAN warning if ieee80211_get_tx_power() returns the INT_MIN value mac80211 internally uses for "unset power level". UBSAN: signed-integer-overflow in net/wireless/nl80211.c:3816:5 -2147483648 * 100 cannot be represented in type 'int' CPU: 0 PID: 20433 Comm: insmod Tainted: G WC OE Call Trace: dump_stack+0x74/0x92 ubsan_epilogue+0x9/0x50 handle_overflow+0x8d/0xd0 __ubsan_handle_mul_overflow+0xe/0x10 nl80211_send_iface+0x688/0x6b0 [cfg80211] [...] cfg80211_register_wdev+0x78/0xb0 [cfg80211] cfg80211_netdev_notifier_call+0x200/0x620 [cfg80211] [...] ieee80211_if_add+0x60e/0x8f0 [mac80211] ieee80211_register_hw+0xda5/0x1170 [mac80211] In this case, simply return an error instead, to indicate that no data is available.
CVE-2025-49734 1 Microsoft 23 Powershell, Windows, Windows 10 and 20 more 2025-12-24 7 High
Improper restriction of communication channel to intended endpoints in Windows PowerShell allows an authorized attacker to elevate privileges locally.
CVE-2020-11639 1 Abb 1 Advabuild 2025-12-20 7.8 High
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
CVE-2024-30896 1 Influxdata 1 Influxdb 2025-12-20 9.1 Critical
InfluxDB OSS 2.x through 2.7.11 stores the administrative operator token under the default organization which allows authorized users with read access to the authorization resource of the default organization to retrieve the operator token. InfluxDB OSS 1.x, Enterprise, Cloud, Cloud Dedicated and Clustered are not affected. NOTE: The researcher states that InfluxDB allows allAccess administrators to retrieve all raw tokens via an "influx auth ls" command. The supplier indicates that the organizations feature is operating as intended and that users may choose to add users to non-default organizations. A future release of InfluxDB 2.x will remove the ability to retrieve tokens from the API. The supplier has stated that InfluxDB 2.8.0 has addressed this issue.
CVE-2025-14517 1 Yalantis 1 Ucrop 2025-12-13 5.3 Medium
A vulnerability was determined in Yalantis uCrop 2.2.11. This affects the function UCropActivity  of the file AndroidManifest.xml. Executing manipulation can lead to improper export of android application components. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-10971 3 Apple, Fermax, Google 3 Ios, Meetme, Android 2025-12-05 N/A
Insecure Storage of Sensitive Information vulnerability in MeetMe on iOS, Android allows Retrieve Embedded Sensitive Data. This issue affects MeetMe: through v2.2.5.
CVE-2025-2157 1 Redhat 1 Satellite 2025-11-21 3.3 Low
A flaw was found in Foreman/Red Hat Satellite. Improper file permissions allow low-privileged OS users to monitor and access temporary files under /var/tmp, exposing sensitive command outputs, such as /etc/shadow. This issue can lead to information disclosure and privilege escalation if exploited effectively.
CVE-2024-10041 2 Linux-pam, Redhat 3 Linux-pam, Enterprise Linux, Rhel Eus 2025-11-21 4.7 Medium
A vulnerability was found in PAM. The secret information is stored in memory, where the attacker can trigger the victim program to execute by sending characters to its standard input (stdin). As this occurs, the attacker can train the branch predictor to execute an ROP chain speculatively. This flaw could result in leaked passwords, such as those found in /etc/shadow while performing authentications.
CVE-2023-3347 3 Fedoraproject, Redhat, Samba 4 Fedora, Enterprise Linux, Storage and 1 more 2025-11-21 5.9 Medium
A vulnerability was found in Samba's SMB2 packet signing mechanism. The SMB2 packet signing is not enforced if an admin configured "server signing = required" or for SMB2 connections to Domain Controllers where SMB2 packet signing is mandatory. This flaw allows an attacker to perform attacks, such as a man-in-the-middle attack, by intercepting the network traffic and modifying the SMB2 messages between client and server, affecting the integrity of the data.
CVE-2025-2241 1 Redhat 2 Acm, Multicluster Engine 2025-11-20 8.2 High
A flaw was found in Hive, a component of Multicluster Engine (MCE) and Advanced Cluster Management (ACM). This vulnerability causes VCenter credentials to be exposed in the ClusterProvision object after provisioning a VSphere cluster. Users with read access to ClusterProvision objects can extract sensitive credentials even if they do not have direct access to Kubernetes Secrets. This issue can lead to unauthorized VCenter access, cluster management, and privilege escalation.