Search Results (29814 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-49681 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: xtensa: xtfpga: Fix refcount leak bug in setup In machine_setup(), of_find_compatible_node() will return a node pointer with refcount incremented. We should use of_node_put() when it is not used anymore.
CVE-2022-49621 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: cpufreq: pmac32-cpufreq: Fix refcount leak bug In pmac_cpufreq_init_MacRISC3(), we need to add corresponding of_node_put() for the three node pointers whose refcount have been incremented by of_find_node_by_name().
CVE-2022-49620 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: net: tipc: fix possible refcount leak in tipc_sk_create() Free sk in case tipc_sk_insert() fails.
CVE-2022-49457 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: ARM: versatile: Add missing of_node_put in dcscb_init The device_node pointer is returned by of_find_compatible_node with refcount incremented. We should use of_node_put() to avoid the refcount leak.
CVE-2022-49447 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: ARM: hisi: Add missing of_node_put after of_find_compatible_node of_find_compatible_node will increment the refcount of the returned device_node. Calling of_node_put() to avoid the refcount leak
CVE-2022-49432 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: powerpc/xics: fix refcount leak in icp_opal_init() The of_find_compatible_node() function returns a node pointer with refcount incremented, use of_node_put() on it when done.
CVE-2022-49324 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: mips: cpc: Fix refcount leak in mips_cpc_default_phys_base Add the missing of_node_put() to release the refcount incremented by of_find_compatible_node().
CVE-2022-49314 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: tty: Fix a possible resource leak in icom_probe When pci_read_config_dword failed, call pci_release_regions() and pci_disable_device() to recycle the resource previously allocated.
CVE-2022-49117 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: mips: ralink: fix a refcount leak in ill_acc_of_setup() of_node_put(np) needs to be called when pdev == NULL.
CVE-2022-49103 1 Linux 1 Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: NFSv4.2: fix reference count leaks in _nfs42_proc_copy_notify() [You don't often get email from xiongx18@fudan.edu.cn. Learn why this is important at http://aka.ms/LearnAboutSenderIdentification.] The reference counting issue happens in two error paths in the function _nfs42_proc_copy_notify(). In both error paths, the function simply returns the error code and forgets to balance the refcount of object `ctx`, bumped by get_nfs_open_context() earlier, which may cause refcount leaks. Fix it by balancing refcount of the `ctx` object before the function returns in both error paths.
CVE-2025-38470 2 Debian, Linux 2 Debian Linux, Linux Kernel 2025-12-23 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: net: vlan: fix VLAN 0 refcount imbalance of toggling filtering during runtime Assuming the "rx-vlan-filter" feature is enabled on a net device, the 8021q module will automatically add or remove VLAN 0 when the net device is put administratively up or down, respectively. There are a couple of problems with the above scheme. The first problem is a memory leak that can happen if the "rx-vlan-filter" feature is disabled while the device is running: # ip link add bond1 up type bond mode 0 # ethtool -K bond1 rx-vlan-filter off # ip link del dev bond1 When the device is put administratively down the "rx-vlan-filter" feature is disabled, so the 8021q module will not remove VLAN 0 and the memory will be leaked [1]. Another problem that can happen is that the kernel can automatically delete VLAN 0 when the device is put administratively down despite not adding it when the device was put administratively up since during that time the "rx-vlan-filter" feature was disabled. null-ptr-unref or bug_on[2] will be triggered by unregister_vlan_dev() for refcount imbalance if toggling filtering during runtime: $ ip link add bond0 type bond mode 0 $ ip link add link bond0 name vlan0 type vlan id 0 protocol 802.1q $ ethtool -K bond0 rx-vlan-filter off $ ifconfig bond0 up $ ethtool -K bond0 rx-vlan-filter on $ ifconfig bond0 down $ ip link del vlan0 Root cause is as below: step1: add vlan0 for real_dev, such as bond, team. register_vlan_dev vlan_vid_add(real_dev,htons(ETH_P_8021Q),0) //refcnt=1 step2: disable vlan filter feature and enable real_dev step3: change filter from 0 to 1 vlan_device_event vlan_filter_push_vids ndo_vlan_rx_add_vid //No refcnt added to real_dev vlan0 step4: real_dev down vlan_device_event vlan_vid_del(dev, htons(ETH_P_8021Q), 0); //refcnt=0 vlan_info_rcu_free //free vlan0 step5: delete vlan0 unregister_vlan_dev BUG_ON(!vlan_info); //vlan_info is null Fix both problems by noting in the VLAN info whether VLAN 0 was automatically added upon NETDEV_UP and based on that decide whether it should be deleted upon NETDEV_DOWN, regardless of the state of the "rx-vlan-filter" feature. [1] unreferenced object 0xffff8880068e3100 (size 256): comm "ip", pid 384, jiffies 4296130254 hex dump (first 32 bytes): 00 20 30 0d 80 88 ff ff 00 00 00 00 00 00 00 00 . 0............. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ backtrace (crc 81ce31fa): __kmalloc_cache_noprof+0x2b5/0x340 vlan_vid_add+0x434/0x940 vlan_device_event.cold+0x75/0xa8 notifier_call_chain+0xca/0x150 __dev_notify_flags+0xe3/0x250 rtnl_configure_link+0x193/0x260 rtnl_newlink_create+0x383/0x8e0 __rtnl_newlink+0x22c/0xa40 rtnl_newlink+0x627/0xb00 rtnetlink_rcv_msg+0x6fb/0xb70 netlink_rcv_skb+0x11f/0x350 netlink_unicast+0x426/0x710 netlink_sendmsg+0x75a/0xc20 __sock_sendmsg+0xc1/0x150 ____sys_sendmsg+0x5aa/0x7b0 ___sys_sendmsg+0xfc/0x180 [2] kernel BUG at net/8021q/vlan.c:99! Oops: invalid opcode: 0000 [#1] SMP KASAN PTI CPU: 0 UID: 0 PID: 382 Comm: ip Not tainted 6.16.0-rc3 #61 PREEMPT(voluntary) Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS rel-1.13.0-0-gf21b5a4aeb02-prebuilt.qemu.org 04/01/2014 RIP: 0010:unregister_vlan_dev (net/8021q/vlan.c:99 (discriminator 1)) RSP: 0018:ffff88810badf310 EFLAGS: 00010246 RAX: 0000000000000000 RBX: ffff88810da84000 RCX: ffffffffb47ceb9a RDX: dffffc0000000000 RSI: 0000000000000008 RDI: ffff88810e8b43c8 RBP: 0000000000000000 R08: 0000000000000000 R09: fffffbfff6cefe80 R10: ffffffffb677f407 R11: ffff88810badf3c0 R12: ffff88810e8b4000 R13: 0000000000000000 R14: ffff88810642a5c0 R15: 000000000000017e FS: 00007f1ff68c20c0(0000) GS:ffff888163a24000(0000) knlGS:0000000000000000 CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033 CR2: 00007f1ff5dad240 CR3: 0000000107e56000 CR4: 00000000000006f0 Call Trace: <TASK ---truncated---
CVE-2023-52325 1 Trendmicro 1 Apex Central 2025-12-22 7.5 High
A local file inclusion vulnerability in one of Trend Micro Apex Central's widgets could allow a remote attacker to execute arbitrary code on affected installations. Please note: this vulnerability must be used in conjunction with another one to exploit an affected system. In addition, an attacker must first obtain a valid set of credentials on target system in order to exploit this vulnerability.
CVE-2025-10226 3 Axxonsoft, Linux, Microsoft 4 Axxon One, Linux, Linux Kernel and 1 more 2025-12-19 9.8 Critical
Dependency on Vulnerable Third-Party Component (CWE-1395) in the PostgreSQL backend in AxxonSoft Axxon One (C-Werk) 2.0.8 and earlier on Windows and Linux allows a remote attacker to escalate privileges, execute arbitrary code, or cause denial-of-service via exploitation of multiple known CVEs present in PostgreSQL v10.x, which are resolved in PostgreSQL 17.4.
CVE-2025-38031 2 Debian, Linux 2 Debian Linux, Linux Kernel 2025-12-19 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: padata: do not leak refcount in reorder_work A recent patch that addressed a UAF introduced a reference count leak: the parallel_data refcount is incremented unconditionally, regardless of the return value of queue_work(). If the work item is already queued, the incremented refcount is never decremented. Fix this by checking the return value of queue_work() and decrementing the refcount when necessary. Resolves: Unreferenced object 0xffff9d9f421e3d80 (size 192): comm "cryptomgr_probe", pid 157, jiffies 4294694003 hex dump (first 32 bytes): 80 8b cf 41 9f 9d ff ff b8 97 e0 89 ff ff ff ff ...A............ d0 97 e0 89 ff ff ff ff 19 00 00 00 1f 88 23 00 ..............#. backtrace (crc 838fb36): __kmalloc_cache_noprof+0x284/0x320 padata_alloc_pd+0x20/0x1e0 padata_alloc_shell+0x3b/0xa0 0xffffffffc040a54d cryptomgr_probe+0x43/0xc0 kthread+0xf6/0x1f0 ret_from_fork+0x2f/0x50 ret_from_fork_asm+0x1a/0x30
CVE-2025-38273 2 Debian, Linux 2 Debian Linux, Linux Kernel 2025-12-19 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: net: tipc: fix refcount warning in tipc_aead_encrypt syzbot reported a refcount warning [1] caused by calling get_net() on a network namespace that is being destroyed (refcount=0). This happens when a TIPC discovery timer fires during network namespace cleanup. The recently added get_net() call in commit e279024617134 ("net/tipc: fix slab-use-after-free Read in tipc_aead_encrypt_done") attempts to hold a reference to the network namespace. However, if the namespace is already being destroyed, its refcount might be zero, leading to the use-after-free warning. Replace get_net() with maybe_get_net(), which safely checks if the refcount is non-zero before incrementing it. If the namespace is being destroyed, return -ENODEV early, after releasing the bearer reference. [1]: https://lore.kernel.org/all/68342b55.a70a0220.253bc2.0091.GAE@google.com/T/#m12019cf9ae77e1954f666914640efa36d52704a2
CVE-2021-47325 1 Linux 1 Linux Kernel 2025-12-18 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: iommu/arm-smmu: Fix arm_smmu_device refcount leak in address translation The reference counting issue happens in several exception handling paths of arm_smmu_iova_to_phys_hard(). When those error scenarios occur, the function forgets to decrease the refcount of "smmu" increased by arm_smmu_rpm_get(), causing a refcount leak. Fix this issue by jumping to "out" label when those error scenarios occur.
CVE-2024-35252 1 Microsoft 2 Azure Storage Data Movement Library, Azure Storage Movement Client Library For .net 2025-12-18 7.5 High
Azure Storage Movement Client Library Denial of Service Vulnerability
CVE-2024-30103 1 Microsoft 6 365 Apps, Office, Office 2019 and 3 more 2025-12-18 8.8 High
Microsoft Outlook Remote Code Execution Vulnerability
CVE-2024-29060 1 Microsoft 3 Visual Studio 2017, Visual Studio 2019, Visual Studio 2022 2025-12-18 6.7 Medium
Visual Studio Elevation of Privilege Vulnerability
CVE-2024-35250 1 Microsoft 23 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 20 more 2025-12-18 7.8 High
Windows Kernel-Mode Driver Elevation of Privilege Vulnerability